Find out where the old unit exhausts
Record the existing model from an accessible label and look up its venting options. The GE JVM3160RFSS installation instructions (31-7000341 Rev. 0, pp. 3–4 and 11) show top exhaust, back exhaust and room recirculation as distinct setups. The model number alone cannot tell you which one was installed. Look for an accessible duct and an exterior termination. If you cannot establish that they connect, have the installer trace the route. Leave concealed sections and any appliance removal to the installer.
Record inside width and height, opening centerline, and where the cap terminates.
Record inside diameter at accessible points, straight runs, turns, transitions and cap.
Take a photo or sketch of accessible points, note duct material and record the cooktop-to-proposed-hood-bottom height. A wall cap's cover measures the cover, so record the actual duct size separately. If the existing unit recirculates and you have no verified outdoor path, budget the duct as new work. Ask about permission for a new penetration where applicable.
Case A · Microwave to hood on a rear rectangular duct
Example inputs. A 30-inch cooktop, a verified 3¼ × 10-inch rear metal duct to outdoors, and a proposed hood bottom 29 inches above the cooking surface. The cabinet opening and exact rear outlet centerline are still unverified.
| Candidate | Documented connection | Next decision |
|---|---|---|
| Broan PM400SSV | Insert. The manual allows a rear 3¼ × 10-inch rectangular outlet. Its published cooktop-to-hood-bottom range is 24–30 inches. | Keep on the shortlist. Check the insert housing, cabinet cutout, rear opening alignment, power connection and fit of the damper. At 29 inches, the height is in range, but the manual calls for a metal liner below 30 inches to protect combustible cabinetry. Verify the liner fit and check the cooktop manual and local clearances. Broan 1105025E (PDF), cabinet and horizontal exhaust · Liner note (PDF) |
| Zephyr ZPO-E30AS | Wall-mounted hood. The specification lists a 6-inch round top outlet and no horizontal outlet. The manual gives 24 inches minimum and 36 inches recommended maximum above the cooking surface. | A direct rear connection is ruled out for this example. Consider it only if the installer can design a route from the top outlet that follows this hood's instructions and fits the space. Zephyr specification, duct configuration (PDF) |
What you can decide today. Hold the Broan model for a cabinet-and-duct fit check. Set the Zephyr aside if keeping a direct rear connection is essential. Bring the cooktop manual as well as the hood's. A matching opening size does not establish that the joints line up, the damper moves freely, or the installed airflow will be adequate.
Case B · Reuse a 6-inch round duct above an old hood
Example inputs. A replacement wall hood would connect to an existing, verified 6-inch rigid metal route: 12 feet of straight duct, one matching 90° round elbow and a matching wall cap with damper. For Zephyr ZPO-E30AS, the top connection matches the specification. The candidate wall mount, height and duct-cover space still need to fit.
Use the Zephyr manual's ducting calculation sheet for this candidate. Add 12 ft + 15 ft + 30 ft = 57 equivalent ft, below the manual's 150 equivalent ft comparison limit. This result covers only the stated route and fittings. It does not estimate airflow or permit reuse on its own. Enter 12, 45 and 150 in the checker length worksheet to reproduce it. If a hidden transition or a different cap is found, revisit the inputs with the installer. Zephyr manual, ducting sheet and mount instructions (PDF)
For the Broan insert, a 6-inch vertical route is also listed, but it needs the right cabinet housing. Use that hood's installation guide for its own duct requirements. The GE microwave's length limits and the Zephyr fitting values do not carry over to it.
Take three records to the installer
- Existing route: outlet direction, inside size, material, known fittings, outside termination and concealed sections to verify.
- Candidate documentation: exact hood and cooktop models, proposed mounting height, cabinet or wall support, and the manual page for the chosen outlet.
- Airflow and make-up air: bring the proposed configuration's documentation and list the fuel-burning appliances and vent types. Ask the building department which capacity and adopted rules it uses.