Manufacturer documentation

Range hood airflow limits by model

Compare what each manufacturer documents before you rely on a lower airflow rating. An electronic setting, a matched accessory and a lab airflow reading have different meanings.

Electronic settingFind the exact model and documented maximum after activation.
Matched accessoryVerify the hood and accessory pair plus the specified duct configuration.
Lab airflow ratingRecord the speed and test pressure. Another rating may describe a different condition.
Use the documentation that matches the mechanism. Take it to the local building department to confirm which value it accepts.

Read the spec sheet before comparing CFM

Start with the exact model, duct outlet and damper. In the HVI performance table, match the same speed and static pressure across models. Keep the open-air blower figure and any installer-set limit in their own columns. Ask the local reviewer which capacity it uses for your proposed configuration.

450 CFMPM400SSV maximum blower figure in open air.
390 → 370 CFMPM400SSV at high speed, 6-inch vertical round outlet, at 0.10 → 0.25 in. w.g.
300 CFMPM400SSV CRT option the installer can apply and document.
Three entries from the Broan PM400SSV documents. The arrow compares two lab test pressures. CRT is a separate setting, and none of these entries is a measurement in your kitchen.
ModelMax blowerHigh at 0.10 in. w.g.High at 0.25 in. w.g.Separate CRT options
PM400SSV450 CFM390 CFM370 CFM300 CFM
PM600SSV650 CFM560 CFM540 CFM400 or 300 CFM

The two high-speed columns use a 6-inch vertical round outlet with the damper included in each model's spec table. The test values and CRT options are separate entries. For example, PM400SSV shows 400 CFM at 0.10 in. w.g. with the rear rectangular outlet and 390 CFM in the 6-inch round row. Switching rows would change the comparison. Choose the row that matches your design and bring the document page to the reviewer. Broan CRT instructions (PDF) · HVI certified directory

Documented U.S. model examples

ModelManufacturer statesWhat to verify
Zephyr Podestà
ZPO-E30AS / ZPO-E36AS
Model documents show a 600 CFM maximum and ACT options of 390 or 290 CFM.Match your model and confirm which ACT setting was selected. The manual says a set limit cannot be reverted. Product page · Specifications & Documents
Broan PM400SSV / PM600SSVThe CRT manual lists a 300 CFM option for PM400SSV and 400 or 300 CFM options for PM600SSV.Confirm the selected setting and corresponding CRT label. Document 1105025E describes an irreversible change. Installation guide, CRT section (PDF)
Broan PM390 familySpec 99043887E lists high-speed airflow of 390 CFM at 0.10 in. w.g. and 375 CFM at 0.25 in. w.g. It separately lists a 440 max blower CFM figure.These are different rating conditions. Ask which rating applies to your review before entering the hood's capacity. PM390 family spec
Bosch HUI56551UC + HUIRED56UCThe U.S. hood spec lists the matching reducer kit and states under 300 CFM with the accessory.Match both part numbers and verify the manual's installation requirements. Confirm availability and local acceptance. U.S. hood spec

What a lower rating changes

A documented limit may change the airflow your local authority considers. It can also change capture performance. Check the range manufacturer's requirements and hood coverage for how you cook. Running a hood on low or restricting it with an unapproved duct reducer does not establish a new documented rating.

Take these records to the building department

  1. Hood model and manufacturer document showing the relevant airflow value and test condition.
  2. Documented setting or accessory, including how the installer will record or label it.
  3. Duct arrangement and list of fuel-burning appliances with their venting and locations.

Check a documented capacity Record the rating for review